Send Message
Home ProductsTecar Therapy Machine

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous

  • 300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
  • 300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
  • 300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
  • 300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
  • 300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
  • 300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous
Product Details:
Place of Origin: China
Brand Name: kaphaTech
Model Number: Smart Tecar
Payment & Shipping Terms:
Minimum Order Quantity: 1PCS
Packaging Details: Alu box
Payment Terms: Western Union, T/T
Contact Now
Detailed Product Description
Certification: CE And Rohs Type: Radio Frequency
Style: Portable Technology: CET RET
Treatment Timer:: 0-45 Minutes Frequency: 300KHz-450KHz
Voltage: AC110V 60Hz , AC220V 50Hz Power: 300W
Work Head: 20mm, 40mm, 60mm , 80mm
High Light:

300KHz Tecar Therapy Machine

,

Stimulation Venous Tecar Therapy Machine

,

RET CET Diathermy Device

300KHz to 450KHz Radio frequency tecar therapy machine RET CET diathermy device for stimulation venous and lymphatic

What is CET RF
Capacitive Electric Transfer (CET) is a method that allows the RF electrical current to be transferred "by capacity" (principle of the electrical capacitor) to the patient's body via a moveable external application electrode. This is covered with an insulating film which acts as dielectric and the body acts as a second plate of the capacitor. A return plate closes the circuit. The electric circulation through the resistive medium formed by the live tissues increases its temperature.

What is RET RF
The Resistive Electrical Transfer (RET), introduced in 1994, is different from the CET in that basically the application electrode is not insulated, allowing the current to be transferred directly to the patient with less dispersion, thus obtaining an increase in temperature at a greater depth.

Tecar Therapy
The Endogenous Thermotherapy based on the principle of capacitive and resistive energy transfer (Capacitive-Resistive Diathermy) has an effect within the biological tissues, activating the body's natural repairing and anti-inflammatory processes from within.

Tecar Therapy is a physical therapy that is part of the endogenous thermotherapy, able to significantly reduce recovery and rehabilitation time by stimulating the activation of all the body's natural repair processes. All this thanks to the application of radiofrequency current that causes a thermal reaction in the tissues that stimulates the body's natural healing response with immediate anti-inflammatory and analgesic effects on muscles, tendons, cartilage or bones ligaments. The two systems, capacitive and resistive, allow the operator to easily adjust the therapy according to the type of pathology. Capacitive transfer for tissues with high water content (muscles), resistive transfer for tissues with the highest resistance and low water content (bones, tendons, adipose tissues).

How Smart Tecar Works ?

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 0

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 1

The closer the working head is to the return pad , the stronger the feeling of heat .

 

Conditions that Benefit from Smart tecar Therapy:

 

1. Sports injuries

2. Muscle pain

3. Joint pain

4. Back pain

5. Neck pain.

6. Sciatica .

7. Frozen shoulder

8. Osteoarthritis

9. Rheumatism

10. Fibromyalgia

11. Reduction in sagging and toning

12.Fat removal

Smart Tecar Effect

The heat speeds up metabolism. This causes blood to flow faster and to become more oxygenated. The result is that more oxygen, and other healing properties of your body`s natural systems, are rushed to the site. The waste is also removed more quickly. The overall result is that your pain is reduced significantly, and the injury is healed more quickly.

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 2

 

Smart Tecar Advantages

1. Double frequencies : 300KHZ and 450KHZ make RET and CET really have deep and shallow differences.The deeper penetration of RET can reach 10CM without energy loss

2. High power In terms of time, similar products are around 80W. Our maximum power is 300W, and practical power is 250W. High power means that the internal components must be of good quality

3. Patent appearance : Unique appearence design

4. Handle diversification : Optional double 80MM handle allows better flexibility in operation and better physiotherapy effect.

5. Large Screen : 10.4-inch LED touch screen

Product Annotations

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 3

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 4

Work heads

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 5

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 6

Screen Interface

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 7

RET and CET handle selection, output Intendency have ten level , working time 0-60min

Parameter

 

Frequency 300KHz-450KHz
Maximun power 300W
Heads size 20/40/60/80mm
Package Dimension 49*46*38CM
Package Weight 17.2KG Alu Box
Technology CET & RET
Electrical Specification AC230V±10%,50Hz±1Hz/ AC110V±10%, 60Hz±1Hz

 

Operation Demo

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 8

Function
Muscle relaxation
Theprecise and aimed effect of the Targeted Radiofrequency Therapy on the hypertonic muscle fibers causes their immediate relaxation. The effect of myorelaxation is primarily based on vasodilation, which occurs immediately during the therapy and is responsible for higher supply of nutrients into the tissue.

Tissue regeneration and healing
The improvement of tissue metabolism is a natural and valuable secondary outcome of the therapy. It leads to faster healing of the traumatized soft tissue and faster reabsorption of post-injury haematomas.

Edema reduction
The walls of the arterioles are enlarged and the precapillary sphincters relaxed, allowing increased local blood perfusion. This leads to an increase of the lymphatic processes (drainage) and subsequently to reduction of the edema.

Pain relief
The principal effect of the Targeted Radiofrequency Therapy–the pain relief–results from muscle relaxation, edema reduction, tissue regeneration and healing.

What are the advantages for patients?

Faster functional recovery. (The beneficial effects are apparent after just a few sessions and improvements can be observed even 24 hours after treatment.)

Treatment is painless and relaxing.

Treatments are safe and have high therapeutic efficacy.

Promotes a sense of well-being, predisposing the subject towards post-treatment physical activity.

Faster rehabilitation.

Traumatology

Tecar Therapy plays a fundamental role in the therapeutic treatment of traumatic pathologies, and represents a source of bioenergy which associates with classic rehabilitative methods in a synergistic manner.Tecar Therapy rebalances tissue physiology through the focused transfer of energy, generating deep, uniform hyperaemia, to reestablish homoeostasis in the cells of the tissues treated. Smart Tecar Therapy resets and reinforces the auto repair capacity of tissues.

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 9

Fat removal

Tecar Therapy proposes an innovative physioaesthetic methodology, using an adaptive system to treat skin imperfections such as localized accumulations of fat. Both automatic and manual application in the natural thermal mode release focused heat in the area treated, which causes metabolic activation and an increase in microcirculation. The areas treated are rich in lipase enzymes which are responsible for lipid metabolism. After a few applications the fat absorption process can be noted, causing an immediate reduction of excess waistline, to quickly achieve well-being.

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 10

Packing List

 

Host 1 unit
RET Handpiece 1pc
RET Tip 3 pcs ( S/M/L , 20/40/60MM)
RET 80MM Handles 2pcs
CET Handpiece 1pc
CET Tip 3pcs (S/M/L , 20/40/60MM)
Return Pad 1pc
Power Supply Line 1pcs
User Manual 1pcs

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 11

FAQ

Is Smart Tecar Therapy painful?

Smart tecar Therapy is not painful. During the treatment the patient feels a pleasant warm sensation, which makes

the therapy extremely comfortable.

 

Is Smart Tecar Therapy dangerous?

SmartTecar Therapy is absolutely not dangerous.Tecar Therapy supplies energy to biological tissues generating a pleasant warmth. Therapy is comfortable and relaxing.

How many Smart Tecar Therapy treatments are necessary?

The number of treatments required depends primarily upon the pathological condition of the patient and how the patient reacts to the therapy. For some acute pathologies, 3 to 5 treatments may be sufficient, while for chronic pathologies a greater number of treatments may be required. Obviously, in order to optimize therapeutic results, correct diagnosis is of fundamental importance.

How frequently can the patient be treated?

Normally the patient can be treated between 2 to 5 times a week. However, if necessary, more than one treatment can be carried out daily. The professional operator will define the number of treatments most suitable for the patient depending upon the state of the pathology.

How long does treatment take?

Smart Tecar Therapy treatments can vary in duration from a few minutes to some tens of minutes, depending upon

the pathology, the required effect and the size of the area to be treated.

Our factory

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 12

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 13

300KHz Radio Frequency Tecar Therapy Machine For Stimulation Venous 14

 

 

Contact Details
Guangzhou Kapha Electronic Technology Co., Ltd.

Contact Person: Ms. Amber Han

Tel: 86-13060901678

Send your inquiry directly to us (0 / 3000)

Other Products